If the fuse is good,check to see if there is voltage to the blower motor,if there is,replace the blower motor.Sometimes,not always,if you bump the blower motor,it will start working,if this happens,then the blower motor is bad,if it does not,the fan switch could be bad,but the relay is usally near the blower motor.Testing it with a test light is the best way to test it,ground one end of the test light,the other end has a point on it.Use the piont of the test light to touch all the legs on the relay,with the key on,and the fan on high.The test light will light up,on almost all the legs,but it will also activate the relay when you touch the right leg of the relay,the relay needs to stay plugged up as you do this.If you can not access the legs of the relay,because of a skirt on the relay,push the point of the relay into the wire that you are testing,or into the plug,near the leg of the relay.The legs I am refuring to,are the prongs on the relay.If the relay clicks and turns the fan on,when you touch the right one,then the fan,and the relay are good,it will be the blower fan switch.Now if you already have high,blower fan,and the lower speeds are the problem,replace the blower resister,It is mounted right next to the blower motor,and has about 7 wires plugged into it.
×