Question about 2000 Ford Taurus

1 Answer

I have a 2000 Taurus SES. Recently, the A/C blower stopped working. I have checked the blower motor fuse, and the blower motor coil fuse, and they both look good. Also, I have replaced the blower motor relay, none of this has fixed my problem. What is my next step?

Posted by on

Ad

1 Answer

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    Top Expert:

    An expert who has finished #1 on the weekly Top 10 Fixya Experts Leaderboard.

    Superstar:

    An expert that got 20 achievements.

    All-Star:

    An expert that got 10 achievements.

  • Ford Master
  • 21,873 Answers

You don't say if it is climate control or manual. Either way, the relay gets power from two fuses, a 10amp for the relay and a 40amp for the actual motor. Did you check them with a meter to see if they have power with the key switch on ?
The relay sends power to the motor. The resistor and fan switch provide the ground circuit for the motor.
Does the motor have power and will it run if you jumper the ground circuit to the body ?

Posted on Aug 01, 2013

Ad

6 Suggested Answers

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
Best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of.(from cars to computers, handyman, and even drones)
click here to download the app (for users in the US for now) and get all the help you need.
Goodluck!

Posted on Jan 02, 2017

Ad
  • 8 Answers

SOURCE: 2000 ford explorer fan blower only works intermittently

On ford vehicles the blower motor resistors are the most common problem when this happens.

Posted on Dec 21, 2008

  • 1 Answer

SOURCE: my blower motor stopped working, front and back of van.

My rear blower motor stopped working and my Brother took the unit apart. He found out that the fan blade had seized up the unit. After he took out blade and sanded down blades, it worked fine. However, I am not sure about your front unit. Good luck.

Posted on Jan 19, 2009

  • 2920 Answers

SOURCE: 2000 f150 blower motor

the blower motor itself....see if its gone bad

Posted on Feb 12, 2009

  • 7 Answers

SOURCE: Blower motor stopped working.

ok to the left of the steering wheel by brake pedal remove fuse panel and look for no. 3 location blower relay after that your going to look for no. 8 blower fuse 40amps after that look for no. 28 its a 10amp fuse this is blower coil relay but if you have puddle lights that fuse is good also runs them !! Hope this helps you out !! Rick from nwi auto acdelco & ford parts dealer !

Posted on Mar 04, 2009

  • 3 Answers

SOURCE: The heater blower on my 1999 Ford ZX2 just stopped

i had the same problem and i did about 3 hours of research and bought a ohm meter got ready to pull it out and i wiggled a wire witch if i remember corectly was the relay harness and it started to blow it was just a bad conection it worked fie after that every one in a while i have to stick my hand under the passenger side and find the harnes and wiggle it back into place hope that helps

Posted on May 26, 2009

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

The blower motor worked then suddenly stopped


At the central junction box, check 15A fuse 16 which feeds the remote climate control (RCC) module. Check 10A fuse 28 which feeds the RCC module and the blower motor relay. Check 40A fuse 6 which feeds the blower motor relay.If the fuses are OK, start the engine (the blower only works while the engine is running). There should be 12V at the PNK/WHT wire connection to the front blower motor speed controller and the blower should be operating. If not, the controller may be defective or the blower motor may have failed

Oct 15, 2012 | 2002 Ford Taurus

1 Answer

Heater and air stopped working on my 2000 Ford Focus zx3


CHECK BLOWER MOTOR FUSE AND RELAY.SEE IF POWER GOING TO BLOWER MOTOR YOU HAVE FAULTY BLOWER MOTOR.IF BLOWER MOTOR FUSE AND RELAY OKAY.IF NO POWER GOING TO BLOWER MOTOR BUT POWER AT AC AND HEATER CONTROL SWITCH. BLOWER MOTOR HAS POOR GROUND OR AC AND HEATER CONTROL SWITCH IS BAD.

Jun 12, 2011 | 2000 Ford Focus

1 Answer

Fixing windows in ford Taurus 2000 One motor was bad when I bought the car, but the other 3 windows stopped working


These motors generally draw high current. Sometimes thru a relay instead of fuses. Check your manual. Some fuses and most relays are under the hood. Substitution will generally find the guilty one.

Sep 07, 2010 | 2000 Ford Taurus

2 Answers

Blower motor stopped working on 99 taurus; no air/heat; need assistance w/troubleshooting. Where should I start?


Start by checking the fuse. If the fuse is good, then either the blower motor is bad or the blower motor resistor pack is bad especially if this problem started with the lose of some of the speeds as in it only worked on high. It can be the speed control itself is bad but rarely does it go bad. You can check the motor by applying 12 volts directly to the motor to see if it is good.

Jan 14, 2010 | 1999 Ford Taurus

1 Answer

Ignition coil location on a 2000 Beetle 1.8L Turbo


vw uses coil on plugs so each plug has a coil under engine cover on top of valve cover check fuses first for your other problem

Jul 10, 2009 | 2003 Volkswagen New Beetle Convertible

1 Answer

What number on the fuse box goes to the windows relay switch?


where is the fuse box and which fuse works the cif. lighter

Mar 22, 2009 | 2000 Ford Taurus

3 Answers

Blower motor stopped working.


https://www.genuineservice.com/genuineservice/en/default?page=genuineService

Go to this site and you can get a copy of your owners manual. Just pic the owner's manual link in the left side task bar.
The relay is located in the interior fuse panel. It should show you a diagram of the fuse panel in the owners manual.

Mar 02, 2009 | 2003 Ford Taurus

1 Answer

Blower motor stop working on 2000 Pontiac GP


Two possibilities I can think of. #1. The blower motor itself is dead, or #2. The blower motor resistor is fried. Blower motor resistor, however, is more known for taking out certain fan speeds, such as the lower fan speeds.

Dec 28, 2008 | 2000 Pontiac Grand Am GT

3 Answers

2000 ford taurus fuse block diagram


Fuse Number 13 it a 20 Amp fuse

Oct 07, 2008 | 2000 Ford Taurus

Not finding what you are looking for?
2000 Ford Taurus Logo

88 people viewed this question

Ask a Question

Usually answered in minutes!

Top Ford Experts

yadayada
yadayada

Level 3 Expert

76691 Answers

Colin Stickland
Colin Stickland

Level 3 Expert

22219 Answers

fordexpert

Level 3 Expert

5537 Answers

Are you a Ford Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...