Question about 2003 Ford Taurus

3 Answers

Blower motor stopped working.

I got a diagnostic test that said blower motor and resistor need replacing on my 2003 Ford Taurus. I replaced both and still no luck. I was told that maybe the blower motor relay or fuse could be bad but I don't know where to find the relay and don't know how to identify relay or fuse because I don't have an owners manual. Has anyone had this problem with the blower motor and how did you resolve it? Just where is the blower motor relay and how do I identify it? Is there a fuse for the blower motor?

Posted by on

  • MaximusMe Apr 10, 2009

    All of your solutions were great and my deepest thanks to all.

×

3 Answers

  • Level 1:

    An expert who has achieved level 1.

    Corporal:

    An expert that has over 10 points.

    Mayor:

    An expert whose answer got voted for 2 times.

    Problem Solver:

    An expert who has answered 5 questions.

  • Contributor
  • 7 Answers

Ok to the left of the steering wheel by brake pedal remove fuse panel and look for no. 3 location blower relay after that your going to look for no. 8 blower fuse 40amps after that look for no. 28 its a 10amp fuse this is blower coil relay but if you have puddle lights that fuse is good also runs them !! Hope this helps you out !! Rick from nwi auto acdelco & ford parts dealer !

Posted on Mar 04, 2009

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

    President:

    An expert whose answer got voted for 500 times.

  • Ford Master
  • 783 Answers

Https://www.genuineservice.com/genuineservice/en/default?page=genuineService

Go to this site and you can get a copy of your owners manual. Just pic the owner's manual link in the left side task bar.
The relay is located in the interior fuse panel. It should show you a diagram of the fuse panel in the owners manual.

Posted on Mar 02, 2009

  • 1 more comment 
  • Chuck Martin
    Chuck Martin Mar 02, 2009

    You can also check for any recalls from this site also.

  • Chuck Martin
    Chuck Martin Mar 02, 2009

    ??

    I give you a link to the website where you could get a copy of your owners manual plus CHECK for open recalls and you give me a thanks for trying rating and the other answer tells you to contact your local ford dealer to check for recalls and you give him a helpful rating?

    Oh well hope you find your answers.

  • Chuck Martin
    Chuck Martin Mar 02, 2009

×

  • Level 1:

    An expert who has achieved level 1.

    Corporal:

    An expert that has over 10 points.

    Mayor:

    An expert whose answer got voted for 2 times.

    Problem Solver:

    An expert who has answered 5 questions.

  • Contributor
  • 12 Answers

You should contact your local ford dealership and ask them to run an OASSIS report for open recals on your car becouse it is a knowen problem and most of the time it is replacing the wire harness for the resistor pack

Posted on Mar 02, 2009

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

2 Answers

A/c blower motor works if I pull power and plug back in until I cut engine off. Then I have to repeat process


Daryl, You may want to check the blower relay/ just switch with one of same type and try and if OK, problem could be the blower motor, wires/plug loose,damaged,burnt or a faulty blower motor resistor. Second link has some trouble shooting of a overheating wire problem, that is to be common in these trucks. Check the attached links,instruction and guides, Good luck
"I hope this helped you out, if so let me know by pressing the helpful button. Check out some of my other posts if you need more tips and info."
DIY 2003 Silverado Blower Motor Resistor
Sparkys Answers Chevrolet Silverado Blower Does Not Work On Any Speed
03 Silverado heater fan problem ChevyTalk FREE Restoration and Repair Help...

Jul 19, 2016 | 2003 Chevrolet Silverado 1500

1 Answer

Front blower motor quit working replaced ignition switch,control module,resister,and blower motor but still doesnt work fuses are all good where do i look next


normally it is the resistor,( relay) then resistor module then motor.
did you test the relay(I believe located under hood, relay/fuse center), If OK check plugs and wires for melting, damage and good connection, grounds should also be checked. Use a volt ohm meter to see if you are getting any power ti motor,etc.
the first link below gives good how to diagnose blower,press the helpful button
GM Blower Motor Resistor Diagnostics by Wells

DIagnose and Replace GM blower Control Module

http://www.gmcproblems.com/tsbs/Envoy/2003

Jan 30, 2016 | 2003 GMC Envoy Xl

1 Answer

98 buick heater stop working


Its faulty blower motor resistor. The low and medium speed on blower motor is controlled by resistor and its actual speed is high. So because resistor is not working, blower motors actual speed which is high is working.


It can be faulty blower motor or faulty blower motor resistor. Get the blower motor inspected. If it's faulty it has to be replaced.


=======

For blower motor testing and replacing, check the link below: ----

Blower motor Testing/replacing for all vehicles?

http://repairhelpcenter.blogspot.in/2012/02/blower-motor-replacing-for-all-vehicles.html

------------

These will help.

Thanks.

Dec 14, 2012 | 1998 Buick LeSabre

2 Answers

Location of the resister for the heater fan 350 ford 2006


Its under dash panel.

HEATER BLOWER MOTOR


Its faulty blower motor resistor. The low and medium speed on blower motor is controlled by resistor and its actual speed is high. So because resistor is not working, blower motors actual speed which is high is working.


It can be faulty blower motor or faulty blower motor resistor. Get the blower motor inspected. If it's faulty it has to be replaced.


=======

For blower motor testing and replacing, check the link below: ----

Blower motor Testing/replacing for all vehicles?

http://repairhelpcenter.blogspot.in/2012/02/blower-motor-replacing-for-all-vehicles.html

------------

These will help.

Thanks.

Nov 28, 2012 | Ford F-350 Cars & Trucks

1 Answer

My ford fusion 2006 the a/c blower motor will stop working on firs speed after half of an hour and i replace the resistor and steel duing the same


I have a 2008 fusion and the main control for the ac and blower will not turn anything on is there a main fuse or relay for that cause i checked the fuses and they were all good

May 02, 2012 | 2003 Ford Taurus

1 Answer

1998 ford taurus blower won't work. Heat won't go on or the a.c. How can this be fixed or what is the cause of the problem?


Check the fuse box under the hood and look for the a/c heater blower fuse, check to see if it's gone bad and needs to be replaced. The other thing to is check if the blower fan works on high setting only, if it does, then the blower motor resistor has gone bad and needs to be replaced. Once you have gone through all the electrical fuse and relay, then good chance that the blower motor needs to be replaced. If you go to Auto Zone they will have the blower motor and resistor if you want to replace that too and they will have the step by step instructions for you to get the job done with common tools. Good luck and keep me posted, be glad to answer more questions you may have. 

Jul 01, 2009 | 1999 Ford Taurus

2 Answers

My blower motor fan speed switch will work only on High.


I had a similar problem with my 03 Taurus. Does your floorboard on the passenger side get wet when it rains really hard? If so, Ford is aware of a defect above the fan motor which is behind the glovebox.
I contacted Ford directly and they had my local ford dealer fix it free and they gave me money towards a new blower motor which shorted out from the leak, it's possible it just your switch if there is no leak but you might need both the switch and blower motor replaced like I did. Hope this helps.

Apr 10, 2009 | 2003 Ford Taurus

1 Answer

Heater stopped working.. blower not working? 1999 ford taurus


sounds like the blower motor resistor which controls blower motor speed has a short and needs replaced.

Jan 25, 2009 | 1999 Ford Taurus

2 Answers

I have a 2006 ford tuarus,


you need to replace the blower motor resistor, the reason it only works on high is that position bypasses the resistor, it is located near the blower motor

Nov 29, 2008 | 2006 Ford Taurus

Not finding what you are looking for?
2003 Ford Taurus Logo

733 people viewed this question

Ask a Question

Usually answered in minutes!

Top Ford Experts

yadayada
yadayada

Level 3 Expert

61037 Answers

Colin Stickland
Colin Stickland

Level 3 Expert

21949 Answers

Fordexpert

Level 3 Expert

5331 Answers

Are you a Ford Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides