I HAVE A 1992 F250 4X4 7.3 DEISEL.THE HEATER FUNCTION SWITCH WILL NOT CHANGA FROM DEFROST TO FLOOR OR MIX! IT IS STUCK ON DEFROST.

Posted by on

  • Anonymous Mar 27, 2014

    Hy heater switch is stuck on defrost

×

1 Answer

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

    Vice President:

    An expert whose answer got voted for 100 times.

  • Master
  • 424 Answers

Check for vacuum leak at recirculation door under the hood. It is white in color. Find some vacuum hose at a parts store that wil replace the broken hose.

Posted on Feb 02, 2009

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Why wont my 2001 ford windstar blow out of vents ? only on defrost?


Air Flow Control
Air flow control is accomplished in the following manner:
  • Primary control is through the function selector knob , mounted on the heater function selector switch, which is part of the heater control .
  • The function selector knob has the following positions: OFF, PANEL, PANEL/FLOOR, FLOOR, FLOOR/DEFROST and DEFROST.
  • The heater function selector switch combines a vacuum selector valve with an internal electrical switch.
  • The vacuum selector valve directs source vacuum to various vacuum control motors (18A318) . Refer to the System Airflow Schematic and Vacuum Control Charts.
  • An internal single-pole electrical switch is also controlled by the selector. The switch controls the electrical supply to the heater blower motor switch (18578) .
  • The position of the function selector knob determines the manner in which the system will operate.
  • Each position of the function selector knob is detented for positive engagement.
  • You probably have a vacuum leak , Pull heater control panel an check for vacuum . A broke vacuum hose or The vacuum selector valve is bad ! Or check for a vacuum hose in the engine compartment being off somewhere !

Mar 08, 2015 | 2001 Ford Windstar

1 Answer

1998 chevy monte carlo , can not switch


Problem is in the vaccum feed pipe (Cracked) or the actual control panel.

Mar 10, 2010 | 1997 Chevrolet Monte Carlo

2 Answers

Heater problem, not very hot & not switching from defrost to floor


either the AC\Heater panel switch on your center dash or the heater box vent door is stuck or not operating. Most likely panel switch or disconnected \ broken vacumm lines at back of switch

Jan 13, 2010 | 1996 Chevrolet Blazer

1 Answer

2005 Ford Focus ZX4 AC switch in dash does not move the blend to control where the heat goes in car.The AC switch which attaches to the button and to the mechanism under the dash but the new switch stopped...


Sounds like there is a foreign object in the heater case. The only way to reapair it is to remove the object by possibly removing the heater case.

Nov 08, 2009 | 2005 Ford Focus

1 Answer

I have the same problem with my windstar blower is fine but is coming cold air but no heat i dont know what to do can any one show me how to fix it thnx


First, feel the heater hoses going into the firewall under the hood. If they are hot, then you have hot engine coolant going into the heater core. If they are not hot, then you either have a bad thermostat or you are very low on engine coolant.

Next you need air flowing through the heater core so it can come out heated through your vents. If the iar is flowing somewhere else, your temp blend door is not moving because the bend door motor is bad or your temp knob on your heater controls is bad. The blend door motor is an electric motor.

------------------------------------------------
Air Flow Control
Air flow control is accomplished in the following manner:
  • Primary control is through the function selector knob , mounted on the heater function selector switch, which is part of the heater control .
  • The function selector knob has the following positions: OFF, PANEL, PANEL/FLOOR, FLOOR, FLOOR/DEFROST and DEFROST.
  • The heater function selector switch combines a vacuum selector valve with an internal electrical switch.
  • The vacuum selector valve directs source vacuum to various vacuum control motors (18A318) . Refer to the System Airflow Schematic and Vacuum Control Charts.
  • An internal single-pole electrical switch is also controlled by the selector. The switch controls the electrical supply to the heater blower motor switch (18578) .
  • The position of the function selector knob determines the manner in which the system will operate.
  • Each position of the function selector knob is detented for positive engagement.
Temperature Control
The temperature control operates in the following manner:
  • Temperature control of the heater system is determined by the position of the temperature control knob (between COOL-BLUE and WARM-RED) of the heater control .
  • This control knob is connected to a potentiometer mounted in the heater control . This potentiometer is electrically connected to the electric blend door actuator that operates the A/C air temperature control door.


e72a310.gif

  • Movement of the control knob from COOL (Blue) to WARM (Red) causes a corresponding movement on the air temperature control door and determines the temperature that the system will maintain.
System uses a reheat method to provide conditioned air to the passenger compartment.
  • All airflow from the blower motor (18527) passes through the A/C evaporator housing .
  • Temperature is then regulated by reheating a portion of the air and blending it with the remaining cool air to the desired temperature.
  • Temperature blending is varied by the air temperature control door, which regulates the amount of air that flows through and/or around the heater core (18476) , where it is then mixed and distributed.
--------------------------------------------------------------------------------------------------------------------------
inside you plenum box:

09f3f8a.gif

Mar 03, 2009 | 1998 Ford Windstar

1 Answer

2004 Pontiac Montana blows cold air in defrost


There is a mix damper inside your duct that controls the heat over heater core and ac evaporator that to your floor and one to your defrost. it is probable an electric actuator, that is not functioning properly. If yu can locate it and manually move it, you might have to remove the actuator motor first, you should be able to figure out your problem, I hope this helps! merry Christmas!

Dec 22, 2008 | 2004 Pontiac Montana

1 Answer

Vacuum diagram 1992 ford taurus


Well as far as knowing exactly which hose to put where i cant help. Other than tell you to buy a chiltons manual at advance auto. Now there is a box in the passenger side floor under the dash of your taurus. this box is actually where the flipper is that switches from floor, to vents, and of course your defroster. So you can reach up there manually and switch yours to defrost. Just turn your heater on and(blower motor) then look for the black box should be like one foot by 1 foot. There will be a little siver selector switch on the side of this box. Just flip this switch by hand and you will make your hot air go up to your defroster, also while you are under there, look for loose vacuum hoses, this is normally cause by children hitting these hoses with their feet and disconnecting them. So i am sure now that you know where to actually look you can fix this problem. Hope this helps ya

Jul 03, 2008 | 1992 Ford Taurus

Not finding what you are looking for?
1992 Ford F250 Logo

Related Topics:

366 people viewed this question

Ask a Question

Usually answered in minutes!

Top Ford Experts

yadayada
yadayada

Level 3 Expert

60792 Answers

Colin Stickland
Colin Stickland

Level 3 Expert

21949 Answers

Fordexpert

Level 3 Expert

5331 Answers

Are you a Ford Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...