Question about Cars & Trucks

1 Answer

Heater fan not working

Where is the fuse?

Posted by on

  • rrblackwell5
    rrblackwell5 Jan 02, 2013

    pulled all the fuses under the dash on the driver's side. 15 amp blade fuses all look good

  • john frink jr Jan 02, 2013

    then I would say test to see if you are receiving juice to the motor.

×

Ad

1 Answer

  • Level 1:

    An expert who has achieved level 1.

    Hot-Shot:

    An expert who has answered 20 questions.

    Corporal:

    An expert that hasĀ over 10 points.

    Problem Solver:

    An expert who has answered 5 questions.

  • Contributor
  • 30 Answers

First you need to check the fuse.

Posted on Jan 02, 2013

Ad

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
Best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of.(from cars to computers, handyman, and even drones)
click here to download the app (for users in the US for now) and get all the help you need.
Goodluck!

Posted on Jan 02, 2017

Ad

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Wheres heater fan on 91 e150


Usually bad blower motor resister mounts into the heater box under hood.

Dec 28, 2014 | Cars & Trucks

1 Answer

Heater fan not working


The three most common problems for heater fans are
  1. Burned-out blower motor resistor. This is usually located on the engine side of the firewall. Sometimes one section of the resistor is burned out but others are still good, so the blower only works on the highest speed settings. If you have a burned-out resistor, check the blower bearings to make sure they are not stiff and causing the motor to draw too much current.
  2. The blower is actually working, but either the intake vent is plugged (I've seen vehicles with the heater core completely blocked by dirt, leaves and insects that came in through the vent), or the heater door is stuck closed.
  3. The motor bearings have gone bad (see # 1). This can cause the fuse to blow, although the resistor usually fries first.
I'm not sure how your car's cabin environmental control system is fused. Check any fuse that might apply, such as Vent/AC, HTR, FAN, etc. Generally you can identify the state of a blade-type fuse by inspection without removing it. If you have a blown fuse, check the blower motor before wasting money on a new fuse that will probably blow. Like any fan, it's supposed to turn easily, and there should not be any roughness or side-slop in the bearings.

Nov 14, 2011 | 2004 Renault 181

1 Answer

My 1991 isuzu trooper heater blower fan is not working, nor when i turn it to the airconditioner the compressor does not engage. i checked all the fuses except the ac relay fuse block, what could the...


if the lower fan speeds dont work but the fastest speed does the heater fan resistor block needs replacing. If the highest fan speed doesnt work leave it on there and check for power at heater blower fan, if power is on one wire and the other is an earth the blower motor fan needs replacing. Use a normal globe test light to check this. If no power on any wires to fan go back and check all fuses in car and under bonnet with same test light. If fuses are ok possible open circuit wire to fan.

Jan 13, 2011 | 2004 Isuzu Rodeo

1 Answer

HEATER FAN QUIT WORKING. IS THERE FUSES?


Yes, the heater fan does have a fuse. If the fuse isn't blown, there's a sensor in the duct work behind the glove box under the dash that controls the fan speeds that you can check.



Dec 26, 2010 | 2006 GMC Sierra

1 Answer

Heater does not work


Check heater fuse.
If fuse good - could be a failure of the blower fan motor or blower control switch.
If fuse bad - bad blower fan motor could have blown the fuse.
DO: check fuse, then blower motor.
Pricing: new blower motor: Duralast PM270 $43.99
new heater control switch: Duralast SW229 $46.99 (without
A/C).
I'd expect your blower resistor to be good - when they fail, the blower only will work on HIGH setting.

Oct 23, 2010 | 1993 Dodge Caravan

1 Answer

Heater fan don't work,don't know which fuse operates heater fan


Hi!!
Look in engine compartment close to battery for fuse box, remove cover and inside cover there is a diagram of fuse/relay locations.
You are looking for a fuse and relay, it should say blower fan or AC blower fan. First check fuse, if Fuse is ok. check Relay.
Good Luck!! Don't forget to rate this post!!

Aug 14, 2010 | 1999 Ford Escort

2 Answers

No air coming out of the vents


It sounds like the heater motor may not be operating. When you switch the heater fan on can you hear the motor running? If not then it may have blown the heater fan fuse, check the fuse's and then try it again. If the fuse is ok then it could be a faulty switch or fan motor.

Apr 02, 2010 | 2004 Chevrolet TrailBlazer

Not finding what you are looking for?
Cars & Trucks Logo

Related Topics:

14 people viewed this question

Ask a Question

Usually answered in minutes!

Top Cars & Trucks Experts