How do i replace blower motor on 2003 ford f 150

Posted by on

Ad

6 Suggested Answers

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
Best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
New users get 2 Free calls (no credit card required) and instant help on almost anything you can think of (from cars to computers, appliances, handyman, and even pets).
click here to download the app (for users in the US for now) and get all the help you need.
Goodluck!

Posted on Jan 02, 2017

Ad
  • 3 Answers

SOURCE: blower motor wont work on any speed

check the AC/Heater fuse

Posted on Aug 20, 2009

Ad
  • 7 Answers

SOURCE: Blower motor stopped working.

ok to the left of the steering wheel by brake pedal remove fuse panel and look for no. 3 location blower relay after that your going to look for no. 8 blower fuse 40amps after that look for no. 28 its a 10amp fuse this is blower coil relay but if you have puddle lights that fuse is good also runs them !! Hope this helps you out !! Rick from nwi auto acdelco & ford parts dealer !

Posted on Mar 04, 2009

  • 1 Answer

SOURCE: My blower motor fan speed switch will work only on High.

I had a similar problem with my 03 Taurus. Does your floorboard on the passenger side get wet when it rains really hard? If so, Ford is aware of a defect above the fan motor which is behind the glovebox.
I contacted Ford directly and they had my local ford dealer fix it free and they gave me money towards a new blower motor which shorted out from the leak, it's possible it just your switch if there is no leak but you might need both the switch and blower motor replaced like I did. Hope this helps.

Posted on Apr 14, 2009

  • 7 Answers

SOURCE: AC blower motor switch inop

You may have a vacuum line disconnected. check your engine and listen for the hissing of the vacuum line.

Posted on May 29, 2009

SOURCE: 2003 ford explorer blower motor works but weak

The doors in the blower/heater/evap housing are sticking because of an issue with the vacuum or elec servo motors or improper computer command

Posted on Sep 28, 2009

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Blower does not work in rear AC 2012 E-150 Van. Suggestions?


check fuse ,if it is good check to see if there is power to the blower if not replace blower motor , if not check for bad relay

Aug 27, 2014 | 2012 Ford E-Series Wagon E-150 XL...

1 Answer

How do I fix the blower fan in my Ford F-150? It's STUCK on HIGH!


the problem is not the fan (blower motor) , it is the resistor in the blower motor hosing under the hood...
open the hood and look over by the passangers side firewall to locate the blower plenum (housing).
There is a plug that has 4 wires and it is plugged dirrectly to the housing.behind that is the resistor configuration that runs the fan at the different speeds ( more resistance = slower fan speed).
It is this part you need to replace.

Mar 23, 2013 | Cars & Trucks

2 Answers

I have a 1998 ford f 150 and the blower motor only works on high


This problem is caused by a defective blower motor speed control resistor.

BLOWER MOTOR LOCATION
The blower motor resistor is located under the glove box. You can locate it by finding a 4 wire connector, directly below the glove box hinge (towards the front of the truck). There are 2 screws holding it in. A mirror is helpful in replacing this, but I managed to replace it without one. You will need a nut driver to remove the screws. My suggestion is to leave the wires connected to the resistor while removing the screws.

Nov 10, 2010 | 1998 Ford F150 Regular Cab

1 Answer

2003 explorer blower motor output weak on all settings


Check for airflow restrictions and proper HVAC door operation. If all is well, compare blower motor current to specifications and replace motor if necessary. Also, make sure that blower is receiving proper voltage from controls.

Aug 22, 2010 | 2003 Ford Explorer

1 Answer

Where is the turn signal electronic flasher located on the 2003 ford f-150


The flasher is in the same relay block as the blower motor relay. It is just off center of the steering wheel column under the dash, behind the knee panel.
It might still have a cover on it, so you will need to take a close look.

Aug 19, 2010 | 2003 Ford F150 Regular Cab

1 Answer

2003 ford explorer blower motor works but weak


The doors in the blower/heater/evap housing are sticking because of an issue with the vacuum or elec servo motors or improper computer command

Sep 28, 2009 | 2003 Ford Explorer

1 Answer

AC blower motor switch inop


the switch is blown. you will need to replace this resistor switch asap.

May 28, 2009 | 1990 Ford F150

Not finding what you are looking for?
Cars & Trucks Logo

Related Topics:

222 people viewed this question

Ask a Question

Usually answered in minutes!

Top Cars & Trucks Experts

yadayada
yadayada

Level 3 Expert

76649 Answers

Colin Stickland
Colin Stickland

Level 3 Expert

22219 Answers

Randy Ohler

Level 3 Expert

14585 Answers

Are you a Car and Truck Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...