Question about 2003 Acura 3.2TL

1 Answer

99 tl. Blower motor relay is not being energized. The blower motor does run when i the relay block. Is the Climate Control Panel bad?

I have replaced the blower transistor....

Posted by on

  • 4 more comments 
  • josh_tandber
    josh_tandber Dec 02, 2012

    correction: jumpered the relay block

  • josh_tandber
    josh_tandber Dec 02, 2012

    Also, the diagnostic shows the bottom dash of the second 8.

  • michael kitchen
    michael kitchen Dec 02, 2012

    what ever

  • josh_tandber
    josh_tandber Jan 15, 2013

    IN MY CASE THE power supply to the blower motor relay (energizes the relay when the ignition is 'on') was broken. I ran a new wire from the fusebox to the relay.

  • josh_tandber
    josh_tandber Jan 15, 2013

    Here are the troubleshooting pages from the Service Manual.

  • josh_tandber
    josh_tandber Jan 15, 2013

    Service Manual:





×

1 Answer

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

    Master:

    An expert who has achieved Level 3.

  • Master
  • 378 Answers

Check the fuse also when changing the resitor you have to take the fuse out and disconnect the battery

Posted on Dec 02, 2012

6 Suggested Answers

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

  • 204 Answers

SOURCE: what might cause blower motor on 2003 acura tl-s

THE FAN SPEED CONTROLL IS BROKEN . THE FAN GENERALLY ONLY HAS ONE SPEED , BUT WHITE AN ADJUSTBLE RESISTANS IT CAN BE LOWERED IN TO ANY SPEED . GET AN NEW ONE

Posted on Oct 12, 2010

keemo68
  • 1263 Answers

SOURCE: blower motor for a 1997 acura tl

one of 2 places either under the dash behind the glove box or under the hood on the passengerside. first i would check the fuse and or fan motor relay. these are located in the box under the hood or under the dash on the drivers side. also i would check the reostat which controls the fan speed this is located near the motor and is held in place by 2 screws and has 2 wires hooked to it. one more thing to check is to make sure the switch is still good

Posted on Aug 29, 2008

samson-1
  • 153 Answers

SOURCE: a/c and heater blower not working anymore....already replaced motor

The blower motor resistor is likely the problem.

Posted on Nov 10, 2008

  • 1596 Answers

SOURCE: problem with air blower...

BlowerMotor Relay is Located On Driver Side in Engine Compartment and is the LARGE Relay in center of box CLOSEST to you If you are Standing On the Driver side of Car This is A Culpret, Also the "BLOWER MOTOR RESISTOR" also can Cause What You describe.
I HAVE PICTERS AND Manual Info But need Email Address to send as FixYa Wont Exept this Type of Files

Blower Unit Components Replacement

Note these items when overhauling the blower unit:


The recirculation control motor, the power transistor ), the blower motor (C), and the dust and pollen filters (D) can be replaced without removing the blower unit.

  • Before reassembly, make sure that the recirculation control linkage and doors move smoothly.
  • After reassembly, make sure the recirculation control motor runs smoothly.

Posted on Feb 12, 2009

motor1258
  • 6674 Answers

SOURCE: were is blower motor 1997 acura tl 3.2?

Check this link. May change your mind.

http://www.autozone.com/shopping/repairGuide.htm?pageId=0900c1528008be4b

Posted on Mar 06, 2009

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

I have a 98 bonneville se. the blower fan only comes on when the knob is all the way up and it ONLY blows heat and absolutely no cold also the air only blows out the defroster and the floor


How did you test the A/C system ? Hook up gauge manifold , test A/C pressures ? Manual or automatic climate control ? The blower motor only working on high means the blower motor resistor is bad ! Did you hook up a scan tool an check high an low pressure switchs inputs to the PCM - engine computer . Does the A/C compressor clutch engage ? turning on the compressor ? Moving the mode switch does nothing . Doesn't move from floor to vent to defrost ? Probably the mode door actuator ! Don't think the HVAC control panel is bad . Just a few little things . Pushing the A/C button on the control panel just send a electrical signal to the PCM , the PCM will energize the A/C clutch relay , turning on the compressor .

The Trainer 40 When the compressor won compress

Blower Motor Problems Auto Repair Help

Do you know how to test automotive electrical circuits ?

Heater Blower Motor Troubleshooting


May 19, 2017 | 1998 Pontiac Bonneville

2 Answers

A.c. cooling fan runs constantly on high even with ignition off and key out


A/C - Heater blower motor ! What make , model and year vehicle ? Manual or automatic climate control ? Could be a bad blower motor control module , a high blow relay contacts stuck closed .

Mar 28, 2017 | Cars & Trucks

2 Answers

Heater blower motor quit...need to find ground for resistor


I suggest you find your fuse/ relay center check fuses and try new relay, I think the relay is 75% at fault most of the time.
Blazerk from Altima forum suggest
Back probe the blower motor Blue/Yellow circuit and tap it to ground, if that doesn't make the blower operate, the blower motor/power transistor assembly is bad. When the blower motor does operate while grounding that circuit, the climate control panel may be faulty, repeat the test from the connector at the control panel to verify the wiring is not damaged. Also, When verifying voltage, Use the power and ground wires to the blower motor. Other grounds may give you faulty readings.
press the helpful button and follow me on fixya

2000 2003 Nissan Maxima Blower Motor Amplifier Resistor Replacement...

found this helpful answer from nissan mechanic on JustAnswer com

Jan 28, 2016 | Cars & Trucks

1 Answer

Heater blower faulty and unrepairable. What other nissan uses same blower heater?


IS IT THE BLOWER MOTOR OR THE CLIMATE CONTROL UNIT ..ALSO THERE IS A IN LINE BLOWER MOTOR RESISTOR THAT BOLTS IN TO THE LOWER DUCTS WHEN THOSE GOT OUT IT CAN ALSO CAUSE THE BLOWER MOTOR NOT TO WORK....HOWEVER IF ITS THE BLOWER MOTOR ANY FROM 95-99 NISSAN MAXIMA WILL WORK ALSO I THINK THE 95-99 NISSAN QUEST WILL WORK..CLIMATE CONTROL WILL WORK FROM OTHER MAXI'S AS LONG AS IT'S THE SAME TYPE(ELECTRONIC OR DIAL TYPE)

Dec 25, 2010 | 1995 Nissan Maxima

2 Answers

Blower motor or resistor?


Yes its the blower motor resistor.

More then likley theres some trash or something in it, or possibly the motor itself is on it's way out. There not that bad to pull out of that body car, just pull it out and see what you can see.

The blower motor is under the glove compartment

You can replace the resistor on your own. Please find a detailed diagram which would guide you to do it.

http://autorepair.about.com/library/images/bl629a-lib.htm

Thanks

Apr 09, 2009 | 2000 Chevrolet Malibu

1 Answer

Problem with air blower...


BlowerMotor Relay is Located On Driver Side in Engine Compartment and is the LARGE Relay in center of box CLOSEST to you If you are Standing On the Driver side of Car This is A Culpret, Also the "BLOWER MOTOR RESISTOR" also can Cause What You describe.
I HAVE PICTERS AND Manual Info But need Email Address to send as FixYa Wont Exept this Type of Files

Blower Unit Components Replacement

Note these items when overhauling the blower unit:


The recirculation control motor, the power transistor ), the blower motor (C), and the dust and pollen filters (D) can be replaced without removing the blower unit.
  • Before reassembly, make sure that the recirculation control linkage and doors move smoothly.
  • After reassembly, make sure the recirculation control motor runs smoothly.

Feb 12, 2009 | 2003 Acura RSX

1 Answer

Blower stuck on high speed


yes it will run on high with the resistor unpluged i would have to say your resistor is bad if it does not work at any other speed than high please rate and let me know -jeff

Aug 26, 2008 | 2003 Dodge Grand Caravan AWD

Not finding what you are looking for?
2003 Acura 3.2TL Logo

114 people viewed this question

Ask a Question

Usually answered in minutes!

Top Acura Experts

yadayada
yadayada

Level 3 Expert

75117 Answers

Colin Stickland
Colin Stickland

Level 3 Expert

22095 Answers

Jeff Turcotte
Jeff Turcotte

Level 3 Expert

7772 Answers

Are you an Acura Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...