Question about 2000 Pontiac Grand Am GT

1 Answer

Blower motor stop working on 2000 Pontiac GP

It just stopped working. Checked fuses and they seemed to be OK. Will not work on any setting, just dead

Posted by on

  • rjones103 Dec 30, 2008

    Just figured it out this morning. Its the motor and I have to get it fixed ASAP as Im going out of town tomorrow. Thanks for the help.

  • Anonymous Mar 19, 2014

    Checked out the fuses they were good,tap

×

1 Answer

  • Level 2:

    An expert who has achieved level 2 by getting 100 points

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

    Vice President:

    An expert whose answer got voted for 100 times.

  • Expert
  • 104 Answers

Two possibilities I can think of. #1. The blower motor itself is dead, or #2. The blower motor resistor is fried. Blower motor resistor, however, is more known for taking out certain fan speeds, such as the lower fan speeds.

Posted on Dec 30, 2008

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Cigarette liter stopped working then the next day the blower motor stopped working, Now the buzzer for head lites being left on stopped working and interval wipers stopped as well. This has been within a...


no power, means, what, cig lighter plug dead,?
try something else there, like a cell charger, still dead.?
if it is truely dead, the fuse is blown.
does head lights work, and engine run?
ok fuses that bad are bad, blown. (blown elements)
ok fuse that look GOOD, can in fact be bad, (tiny cracks.)
we never fail to test good looking fuses or go nuts for sure.
you can test fuse 3 ways.
1: DMM ohms, 0 ohms reading
2: voltmeter shows, 12v, on both sides of fuse, key on.
3: a fuse tester dealy bob at any autostore. (ill pass)
there are other ways, but are way too complex to type.
(ok a battery powered test light , yes, all auto stores sell them.
glow with a good fuse)
bingo?

Sep 03, 2013 | 1991 Honda Accord

2 Answers

2000 jeep cherokee


i think the refrigerant u added is not of spreme quality.

i think that may be the fault.

Jun 16, 2008 | 2000 Jeep Cherokee

1 Answer

2000 pontiac grand prix the ac blower stopped working we replaced it and still doesn't work it just comes on one in awhile. after replacing blower motor, then power door locks stop working replace


All these problems do sound as electrical of course but ecerything that you have mentioned is all on separate circuits which is odd. More than likely the blower motor situation is the resister. The window problem could be a number of things but I can tell you that all the wiring goes through the main drivers swtich so it could be just that switch but of course you would need to test before you just go out and but one but it is a common problem. The lights could be several things as we;; but would check the ambient light sensor which is located up in the center dash near the light that flashes for you security. You car didn't happen to get wet on the inside ? In any case I hope this helps.

Oct 24, 2012 | 2000 Pontiac Grand Prix

1 Answer

My A/C blower stopped working completely. First it was the number one setting, then it progressed to number two, and so on until finally all five settings dont work. I checked fuses and they were good....


the blower motor is drawing too much amperage and has blown the resistor, start with checking voltage from the switch to the resistor then to blower motor, if the resistor is blown replace it and the blower motor

Oct 28, 2010 | 2001 Pontiac Grand Prix

1 Answer

The heat index is only 110 degrees, so my 2003 Pontiac Montana's blower motor decided to stop working. I checked the fuses located under the hood, but they look good. Any suggestions on what may be the...


Look above where the passengers feet would be ,
the blower moror should be there , tap on the
housing with a blunt object , while its on.
If it runs its the motor.

Aug 12, 2010 | 2003 Pontiac Montana

2 Answers

My AC was first only working at the max setting now not at all


go for the reostat which is all in one with the blower motor ,expensive part though

Jun 03, 2010 | 2002 Pontiac Grand Prix

1 Answer

The blower motor doesn't work


there is a curcuit that drops power for the lower speeds a "rheostat" that has gone duff between the switch ( or in it) and the fuse amnd motor

Dec 22, 2009 | 2002 Pontiac Montana

1 Answer

Blowers Stopped Working Focus 99 1.6 Ghia


check for power at the blower motor. then check if it has good ground . ground wire is black/orange and goes through blower switch, then to ground. If you ground the black/orange wire at the motor and it works, you either have a bad blower switch or wire connection (I do not have a diagram for your car, this is based on a 2000 2.0 focus) the wire ends up at the left A pillar. black wire.

Oct 07, 2009 | 2000 Ford Focus

1 Answer

Heater/Cooling problems on 2000 Acura RL


Check the fuse for your blower motor if it is OK the Blower Motor may be bad or you may have a loose wire to or from the it have it checked if fuse is good

Mar 24, 2009 | 2000 Acura 3.5RL

1 Answer

Heat blower fan not working


it seems like u have either a bad switch or bad blower motor.

Feb 26, 2009 | 2000 Oldsmobile Intrigue

Not finding what you are looking for?
2000 Pontiac Grand Am GT Logo

Related Topics:

404 people viewed this question

Ask a Question

Usually answered in minutes!

Top Pontiac Experts

yadayada
yadayada

Level 3 Expert

60769 Answers

Colin Stickland
Colin Stickland

Level 3 Expert

21949 Answers

Jeff Turcotte
Jeff Turcotte

Level 3 Expert

6811 Answers

Are you a Pontiac Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...