1 Answer

Diesel truck will not start

What would cause low power to the glow plug relay? I only get 12volts to the large volt with the double yellow wire.

Posted by on

1 Answer

  • Level 1:

    An expert who has achieved level 1.

  • Contributor
  • 1 Answer

Maybee there is a short in the wiring...Or try replacing the glow plugs and glow plug relay..

Posted on Jan 05, 2009

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

2008 Isuzu cranks but does not start,plenty diesel at injectrs


Hi did you check the glow plugs if not get a small piece of wire plus 12 volt bulb connect it to the wire that connected to the glow plugs turn ignition on and see if it lights if not check the fuses plus the cold start relay after that you can fit a piece of wire from the battery to the glow plugs then try to start it. best of luck let me know how you get on

Feb 03, 2015 | Isuzu Cars & Trucks

1 Answer

Hiace starting problems


Is the battery in a good condition, it a diesel engine? If so the glow plugs would be the first point of call. Check for power at the glow plug main wire feed, if you have power there then a wiring fault can be ruled out. If not check your glow plug relay and associated wiring. If you have power, I think from memory its only 11 volts, remove the power balance rod that runs across the top of your glow plugs. Then remove the glow plugs and connect them across a battery hold the threaded body of the glow plugs and the negitive terminal and use a piece of wire to connect the small fine threaded end to the positive terminal on the battery. The glow plug should glow a hot bright red within a few seconds of being connected. If it doesnt it is faulty. 1 faulty glow plug puts strain on the other glow plugs. Id replace all 4 if any are faulty. I hope this helps.
tyl

Mar 18, 2014 | Toyota Cars & Trucks

1 Answer

Truck wont start, but only if you hear a click


I copied this from my GM service manual for 1982 6.2 diesel.

1. If the glow plug relay is not clicking on and off then turn the ignition to the RUN position and connect a 12V test light to ground and touch the pink/black wire in the glow plug relay connector.

2. If the light is off repair the open cicuit in the pink/black wire to the splice.If the light is on then touch the light blue at the glow plug relay connector.

3. If the light is off replace the glow plug relay. If the light is on, disconnect the connection at the thermal controller and touch the black wire in the connector.

4. If the light is off, repair the open circuit in the light blue wire from the thermal controller to the glow plug relay. If the light is on repair open circuit in black wire back to a splice. If no trouble is found replace the controller.



You should also get your hands on this Haynes book. Diesel Engine Repair Manual, part # 10330. Excellent coverage on the 6.2 and 6.5. In it, they say that early 82\'s have a hole at the number 2 hole on the pin connector of the wire harness for the thermal controller. this allows dirt in there and corrodes the pins. Remove the connector and clean thoroughly the pin area on the connection and controller. Seal the hole with some silicone. If things are still acting up, replace the wire harness connector.



Hope some of this helps.

Jan 19, 2014 | 1983 GMC C1500

1 Answer

Starting issue, I have a 1993 ford f250 7.3l pre powerstroke. I started the motor and it stalled out like there was a short, now when i turn the key my glow plugs do not fire and wait to start doesnt show...


On some Models the glow plug Relay does not have an integrated Power Relay. This means there is a second Relay before the glow plug Relay that feeds it power.

You should check the wires running to the glow plug Relay for power with the key ON. Check some other wires off of the Ignition switch to make sure your 20 year old Ignition switch is good.

There are some sites which show vehicle wiring. Autozone has a free section after Registering your vehicle but it takes a little sorting through the Help section. There should be a fuse to protect the above Relays.

Make sure you find the Diesel-equipped wiring circuit. Diesel ignitions are different from gas units.

Dec 27, 2013 | Ford F250 Cars & Trucks

1 Answer

Hyundai Accent 1.5 Diesel. Intermittent problem with starting. Sometimes starts and runs fine. However sometimes on starting car will not run above 750 rpm and throws out HUGE clouds of black smoke. ...


it sounds like a glow plug issue. perhaps a bad glow plug relay. I would think its the relay if the problem comes and goes. If it were a bad glow plug the problem would be constant. check for volts at the glow plugs next time the car acts up. If you find no volts, tap on the glow plug relay next time you turn the key on. This may cause it to activate. if so then replace relay

Jan 05, 2011 | 2003 Hyundai Accent

1 Answer

7.3 Liter Diesel starts hard in morning, ok if not left more than 8 hours. How to check the Glow Plugs?


Your glow plug relay is located on the top of the engine on the right side toward the front. Some models there are 2 solenoids. A large one toward the front and a smaller one right behind it. The glow plug relay is the smaller one toward the rear. The larger front one is the intkae heater relay. To test the glow plug relay turn engine to on. dont start it. both of the large terminals should have power with key on. then turn engine off. only one large terminal should have power. If when you turn engine to on you only have power on one side then go to this test. Turn engine on and test smaller wire. it should have power. If it does replace the relay. If the smaller wire does not have power you have an ignition problem or power (wiring) problem to the relay. Also note the engine needs to be cold. If temp of engine is over 130 the computer will not turn the glow plug circut on! Most of th time this is what fails and not your glow plugs.

Oct 27, 2010 | 1996 Ford F350 Crew Cab

1 Answer

Where is the glow plug controller located on 7.3 f250


Your glow plug relay is located on the top of the engine on the right side toward the front. Some models there are 2 solenoids. A large one toward the front and a smaller one right behind it. The glow plug relay is the smaller one toward the rear. The larger front one is the intkae heater relay. To test the glow plug relay turn engine to on. dont start it. both of the large terminals should have power with key on. then turn engine off. only one large terminal should have power. If when you turn engione to on you only have power on one side then go to this test. Turn engine on and test smaller wire. it should have power. If it does replace the relay. If the smaller wire does not have power you have an ignition problem or power (wiring) problem to the relay.

May 01, 2010 | 2002 Ford F250 Super Duty SuperCab

2 Answers

Toyota hilux 3ltr diesel,i put new glow plugs in about 3 weeks ago & it fixed the starting problem going fine.now it just started not starting when it is cold checked wiring has power to glow plugs...


Double check your fuel filter and replace as necessary. Also replace your coolant temp sensor. I would also pull out each glow plug and bench test with heavy cables and make sure they do glow red. It very well could be a couple of the glow plugs have failed due to quality. Let me know what you find.

Apr 19, 2010 | 1999 Toyota 4Runner

2 Answers

Hi _ i have a problem with my ford its f-350 7.3l diesel . this truck doesent start fast and gets alot of smoke when it start every day i need to put choke in it


check your glow plug relay (located in front of and to the passengers side of the fuel filter) with a multimeter. there will be 4 wires going to the relay two large and two small. with the key off there should be around 12 volts to the one large post and none to the other if there is none to either of the large posts there is a short somewhere between the battery and the relay. if there is voltage to one of the posts turn the key so the wait to start light comes on, and quickly go check the post that didn't have voltage. If the voltage reads below say 10 volts it is time for a new relay( napa part number gpr-109 not the original but alot cheaper been running it for almost a year now no hicups) If relay comes up ok have your batteries load tested, and if they come back clean it is probably safe to say you have more than a few bad glow plugs.

Dec 30, 2009 | 1997 Ford F350 Crew Cab

1 Answer

Glow plugs causing starting problem


if you need connectors and terminals for the glow plug connections under the valve cover, Ford sells then so you don't need a whole $600 harness.

info for your use

Section 03-07B: Glow Plug System 1996 F-250, F-350, F-Super Duty Equipped with 7.3L Diesel Engines Workshop Manual
DESCRIPTION AND OPERATION Glow Plug System The 7.3L diesel engine uses a glow plug system which preheats air in the combustion chamber to improve cold engine starting. The system consists of eight glow plugs, the glow plug control module (12B533), powertrain control module (PCM) (12A650), engine oil temperature (EOT) sensor and barometric pressure sensor (BARO sensor) (12A644). The glow plug system is electronically controlled by the powertrain control module. The powertrain control module energizes the glow plugs immediately after the key is placed in the ON position and then determines how long the glow plugs will be on according to the engine oil temperature and the barometric pressure. The required time for the glow plugs to be energized decreases as the engine oil temperature and barometric pressure increase. The glow plugs are self-regulating, and the powertrain control module controls relay ON time. The powertrain control module protects the glow plugs by energizing them for short durations if the battery voltage is abnormally high.

Possible Causes: Insufficient glow plug ON time will not allow enough heat to accumulate in the combustion chamber to easily facilitate starting. If the glow plug system ON time does not meet any of the specifications in the accompanying chart the problem is most likely a faulty wire harness connection, ground connections or glow plug relay.

If the glow plug resistance to ground is high, the most likely causes are an open UVC (under valve cover) harness or open glow plug.
--------------------------------------------------------
Relay Operation
Install a DVOM on the glow plug feed side of the glow plug relay (large stud with two wires connected). Turn the ignition key to the ON position but do not attempt to start. Note the time in seconds from when the key is turned on and the glow plug relay energizes until the glow plug relay de-energizes. The glow plug relay makes a loud click noise which is easily heard when it energizes and de-energizes. The dome light will dim and the dash voltmeter will dip when the glow plugs are drawing current from the battery. Compare the times measured to the table (time will be affected by engine temperature, battery condition and vehicle altitude). The voltage at the glow plug feed terminal may vary from 9 to 12 volts depending upon battery condition.
--------------------------------------

-----
If battery voltage not present check for B+ at power supply terminal (terminal with single large wire). Power for glow plug power supply is supplied from starter relay through two fusible links at solenoid.
Glow Plug Operation
Disconnect all of the glow plug/injector harness connectors from the valve cover gaskets. With the pigtail installed, measure glow plug resistance to ground (preferably B-). A resistance measurement of .1 to 6 ohms indicates a good glow plug.



Glow Plug Harness Continuity
Measure for continuity from the connector harness to the glow plug feed terminal on the glow plug relay. Resistance should be less than 5 ohms.
Incorrect measurements will result if all glow plug/injector connectors to valve cover are not disconnected.

---------------------------------------------------
Glow Plug Relay The glow plug relay (12A343) has a plastic base and two mounting bolts. It is operated by the powertrain control module (PCM) (12A650) which senses engine oil temperature, PCM voltage and barometric pressure. When the engine oil temperature or the barometric pressure is low, the PCM activates the glow plug relay and the glow plugs. If the PCM voltage is too high, the powertrain control module deactivates the glow plug relay and the glow plugs immediately energize for a shorter duration, decreasing the modulation of the duty cycle.
-----------------------------------------------
Glow Plug Removal
  1. stj~us~en~file=ani_caut.gif~gen~ref.gif WARNING: THE RED-STRIPED WIRING HARNESS CARRIES 115V DC. SEVERE ELECTRICAL SHOCK MAY BE RECEIVED. DO NOT PIERCE.
    Remove valve cover (6582). Refer to Section 03-01D .
  1. Disconnect glow plug electrical connector using a pair of pliers.
  1. Remove glow plug using 10mm socket.
  1. Clean and inspect glow plug tip for damage. Replace if damaged.
Installation
  1. Install glow plug and tighten to 19 Nm (14 lb-ft).
  1. Connect glow plug electrical connector. Make sure glow plug wiring is routed to avoid moving parts.
--------------------------------------------------------------
Glow Plug Control Glow plugs are used to warm the cylinders to improve cold-engine starting. The PCM uses the engine oil temperature (EOT) sensor and barometric pressure (BARO) sensor to determine how long the glow plugs will be on. The PCM energizes the glow plugs longer if the engine is very cold or if the barometric pressure is low at high altitudes.
The PCM controls the relay that supplies power to the glow plugs with the glow plug control (GPC) signal. When the GPC signal is grounded by the PCM the relay closes, turning the glow plugs on.
The glow plugs are controlled by the following sequence:
  1. PCM energizes the glow plugs.
  1. The PCM energizes the glow plugs immediately after the ignition is placed in the ON position.
  1. The PCM then determines how long glow plugs will be on based on EOT sensor and the BARO sensor. The required time to warm up the cylinder decreases the engine oil temperature and barometric pressure increases at low altitudes.
Glow Plug Lamp Control The glow plug lamp (GPL) signal controls the WAIT TO START light located on the instrument panel. This light is used to indicate when to start the engine. The cylinders are being warmed by the glow plugs during and after this light is lit. The PCM energizes the glow plug lamp longer if the engine is very cold or if the barometric pressure is low.
When the GPL signal is brought low, the "Wait to Start" lamp is turned on.
The glow plug lamp is controlled by the following sequence:
  1. PCM lights the WAIT TO START light after a key on reset occurs.
The PCM determines the glow plug lamp activation time based on engine oil temperature, barometric pressure and battery voltage.
  1. PCM turns off the WAIT TO START light.
The glow plug lamp is turned off when the timer counts to the number of seconds specified by the PCM. The glow plugs will normally remain on longer than the "Wait to Start" lamp.
-----------------------------------

Mar 14, 2009 | 2004 Ford F350

Not finding what you are looking for?
Cars & Trucks Logo

Related Topics:

186 people viewed this question

Ask a Question

Usually answered in minutes!

Top Ford Experts

yadayada
yadayada

Level 3 Expert

60667 Answers

Colin Stickland
Colin Stickland

Level 3 Expert

21936 Answers

Fordexpert

Level 3 Expert

5331 Answers

Are you a Ford Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...