Question about Pontiac G6

1 Answer

My blower fan does not work at all on the first setting but works perfectly on the 2nd, 3rd, and 4th setting.

Posted by on

1 Answer

  • Level 2:

    An expert who has achieved level 2 by getting 100 points

    MVP:

    An expert that gotĀ 5 achievements.

    Governor:

    An expert whose answer gotĀ voted for 20 times.

    Scholar:

    An expert who has written 20 answers of more than 400 characters.

  • Expert
  • 71 Answers

They have a resistor in the motor that controls the speed usually only 4th works when they go but i have seen only one setting stop working before. heres a step by step to replace it.
Under the glove compartment you will find a plastic cover thats about a foot by 1/2 foot, just pull that off. Then you will be able to see the blower and a plug that has 4 wires comming out of it. Unplug it and take the 2 small hex blots out, then the resistor will slide out easily. Screw the new one in, plug back in, replace the cover and your good to go.

Posted on Nov 28, 2008

  • RONNIE SPEEDY Jan 11, 2013

    Thank you so much for the info...worked great...little stiff coming out, but once out new one slid right in and works perfectly again.

×

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

2 Answers

1991 toyota crown 2.4 auto diesel wont go into 4th gear


Joe there is a way to test the transmission control computer to see if any trouble codes are present> I will check my manuals and get back with on this by Friday 3/28

Mar 23, 2014 | 1991 Toyota Cressida

1 Answer

2007 Chevy Avalanche 3rd and 4th gear are not working


From what you are describing, it is possible either the 3-4 actuator is no longer playing with the 3rd & 4th clutch packs, only way to know for certain is to hook up the good ol' pressure gauge to trans. system, yeah, you think the Chevrolet dealer should know this right?

Sell it now if you can!
Smiles

Mar 02, 2014 | 2007 Chevrolet Avalanche

1 Answer

No air/heat coming through vents


u more then likely have a bad blower motor resistor

Jun 20, 2013 | 2000 Chevrolet Blazer

1 Answer

Interior fan not blowing on first two settings ... works fine on 3rd & 4th


It sounds to me like your problem Is a bad "blower motor resistor".
It is located behind the glove box on top of the evaporator box!
Good luck!

Jan 21, 2011 | 2008 Ford Escape Hybrid

1 Answer

Blower does not operate


common problem . lots of causes. 1st heck your fuses. 2nd under relays. 3rd blower could be bad. they burn up over time. 4th blower switch could be bad. 5 th blower resistor could be bad

Dec 30, 2009 | 1989 Buick LeSabre

1 Answer

Heater/ac fan only work on High setting. Used to only work on 3rd and 4th setting.


you need a blower resistor it's located behine the glove box. open the glove box and push in the tabs on the side and it will drop down to give you access to the resistor

Nov 16, 2009 | 2002 Jeep Liberty

1 Answer

What different gear box can fit honda integra xsi vtec 1600cc b16a? i want to change my gear box ,and i want to know what exactly other gear box can fit my car?thanks its a integra bot the product can show...


J1/S1 Found in: Integra XSI/RSI (DA6) Type: Cable 1st: 3.230 2nd: 2.105 3rd: 1.458 4th: 1.107 5th: 0.848 R: 3.000 FD: 4.400 Y1 Found in: CRX/Civic (optional LSD) Type: Cable 1st: 3.166 2nd: 2.052 3rd: 1.416 4th: 1.103 5th: 0.870 R: 3.000 FD: 4.266 YS1 Found in: Integra 92-93 XSI/RSI (DA6, DA9) Type: Cable 1st: 3.307 2nd: 2.105 3rd: 1.458 4th: 1.107 5th: 0.880 R: 3.000 FD: 4.400 S80 Found in: Integra Type R 98+ (LSD) Type: Hydraulic 1st: 3.230 2nd: 2.105 3rd: 1.458 4th: 1.034 5th: 0.787 R: 3.000 FD: 4.785 S80/Y80 Found in: JDM SiR-G (optional LSD) Type: Hydraulic 1st: 3.230 2nd: 1.900 3rd: 1.360 4th: 1.034 5th: 0.787 R: 3.000 FD: 4.400 Y21/Y80/S80/S4C Found in: JDM 96-97 Integra R(LSD) JDM Civic R [EK9](LSD) JDM Civic SiR [EK4, EG6] JDM CR-X DEL SOL SIR (EG2)(optional LSD) USDM DEL SOL VTEC (EG2)(OPTIONAL LSD) Type: Hydraulic 1st: 3.230 2nd: 2.105 3rd: 1.458 4th: 1.107 5th: 0.848 R: 3.000 FD: 4.400

Jun 08, 2009 | 1990 Honda CRX

2 Answers

Toyota tacoma heater fan runs slowly in the 3rd & 4th positions


Using a voltmeter, the resisted voltage values for the fan motor are as follows:
LOW- 3 VDC
Med LOW - 6 VDC
Med HIGH - 9 VDC
High - 12 VDC

The fan resistor gets 12 volts from each position of the fan switch, and the 12 VDC is then lowered thru each of the 3 internal resistors inside the fan resistor. My guess is that the resistor has failed, and the resistance wires contained on it may have meshed together. The resistor is on the black box between the blower motor housing and the center of the dash. 2 phillips screws hold it in. Easy to remove/replace. Hope this helps, and thanks for choosing FixYa.

Nov 23, 2008 | 1983 Toyota Camry

Not finding what you are looking for?
Cars & Trucks Logo

Related Topics:

872 people viewed this question

Ask a Question

Usually answered in minutes!

Top Pontiac Experts

yadayada
yadayada

Level 3 Expert

61168 Answers

Colin Stickland
Colin Stickland

Level 3 Expert

21949 Answers

Jeff Turcotte
Jeff Turcotte

Level 3 Expert

6812 Answers

Are you a Pontiac Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...