1999 cadillac escalade new blower motor new modeul new relay no blow

All fuses are good in fuse panel and under the hood

1 Answer

Anonymous

Level 3:

An expert who has achieved level 3 by getting 1000 points

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

Brigadier General:

An expert that has over 10,000 points.

  • Master 6,468 Answers
  • Posted on Mar 27, 2012
Anonymous
Master
Level 3:

An expert who has achieved level 3 by getting 1000 points

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

Brigadier General:

An expert that has over 10,000 points.

Joined: Mar 13, 2012
Answers
6468
Questions
0
Helped
2133858
Points
13357

Check the resister under the dash below the glove box its a flat plug with about 6 wires also see how many wires going to it a burned so when you go to the dealer for the resister you can get the connectors

5 Related Answers

Anonymous

  • 8 Answers
  • Posted on Dec 21, 2008

SOURCE: 2000 ford explorer fan blower only works intermittently

On ford vehicles the blower motor resistors are the most common problem when this happens.

Ad

Anonymous

  • 379 Answers
  • Posted on Jan 13, 2009

SOURCE: 1992 cadillac deville - hvac blower motor does not shut off.

replace the relay , when a relay sticks like that , a good test is to slap it with something like the handle of a screw driver , see if it un-sticks , its not a fix , just a test . cheers'

Ronnie Wilson

  • 1596 Answers
  • Posted on Feb 07, 2009

SOURCE: 2005 Town Country front blower motor inop fuse/relay ok

Break Down And Replace The Blower Motor


REMOVAL

WARNING: ON VEHICLES EQUIPPED WITH AIRBAGS, DISABLE THE AIRBAG SYSTEM BEFORE ATTEMPTING ANY STEERING WHEEL, STEERING COLUMN, OR INSTRUMENT PANEL COMPONENT DIAGNOSIS OR SERVICE. DISCONNECT AND ISOLATE THE BATTERY NEGATIVE (GROUND) CABLE, THEN WAIT TWO MINUTES FOR THE AIRBAG SYSTEM CAPACITOR TO DISCHARGE BEFORE PERFORMING FURTHER DIAGNOSIS OR SERVICE. THIS IS THE ONLY SURE WAY TO DISABLE THE AIR-BAG SYSTEM. FAILURE TO TAKE THE PROPER PRECAUTIONS COULD RESULT IN AN ACCIDENTAL AIRBAG DEPLOYMENT AND POSSIBLE PERSONAL INJURY OR DEATH OR DEATH.

NOTE: The blower motor is located on the passenger side of the vehicle under the instrument panel. The blower motor can be removed from the vehicle without having to remove the HVAC housing.

  1. Disconnect and isolate the negative battery cable.
  2. Remove the passenger side cowl trim panel.
  3. Position the carpet to access the front upper screw that secures the air inlet housing.
  4. Remove the recirculation door actuator.
  5. Disconnect the blower motor wire lead connector from the blower motor resistor or power module, depending on application.
    1. Remove the one screw (from the top) that secures the lower air inlet housing to the upper air inlet housing.
    2. Remove the four screws (from the bottom) that secure the lower air inlet housing to the upper air inlet housing and remove the lower HVAC housing.
    3. Push the rubber grommet through the opening in the lower air inlet housing.
    4. Route the blower motor wire lead through the opening in the lower air inlet housing and remove the lower air inlet housing from the vehicle.
    5. Position the recirculation-air door as necessary to access and remove the three screws that secure the blower motor to the lower half of the HVAC housing.
    6. Gently flex the recirculation air door downward to gain access to remove the blower motor from the HVAC housing. NOTE: To aid in installation, note the position of the blower motor mounting tabs prior to removal
      1. Remove the blower motor from the HVAC housing by rotating and tilting the blower motor as necessary.
      INSTALLATION

      1. Gently flex the recirculation-air door downward to gain access to install the blower motor into the HVAC housing.
      2. Position the blower motor to the HVAC housing and tilt and rotate the blower motor as necessary to install it into the HVAC housing.
      3. Align the blower motor mounting tabs to the locations noted during removal and install the three screws that secure the blower motor to the HVAC housing. Tighten the screws to 2 N·m (17 in. lbs.).
      4. Route the blower motor wire lead through the opening in the lower air inlet housing and seat the rubber grommet.
      5. Position the recirculation door pivot shaft into the lower air inlet housing and install the inlet housing.
      6. Install the four screws (from the bottom) that secure the lower air inlet housing to the upper air inlet housing and the lower HVAC housing. Tighten the screws to 2 N·m (17 in. lbs.).
      7. Install the one screw (from the top) that secures the lower air inlet housing to the upper air inlet housing. Tighten the screw to 2 N·m (17 in. lbs.).
      8. Connect the blower motor wire lead connector to the blower motor resistor or power module, depending on application.
      9. Install the recirculation door actuator.
      10. Reposition the carpet.
      11. Install the passenger side cowl trim panel.
      12. Reconnect the negative battery cable.
      13. Perform the heater-A/C control calibration procedure.

Anonymous

  • 1 Answer
  • Posted on Mar 07, 2009

SOURCE: 1999 vw heater blower dont work

My daughter has a 99 Beetle GL and the A/C and fan went out. It's the A/C haeadunit that needed to be replaced. The switches short out and you have to replace the whole piece. VW charges about $225 for the part Hope that helps

Anonymous

  • 102 Answers
  • Posted on Mar 31, 2009

SOURCE: 1999 VW Passat. Head lights Blower motor blinkers

yes, it's called the load reduction relay and it is in the 13 fold relay panel under driver side dash.

Ad

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
1answer

The AC in Rear want blow in my2002 Escalade

Yes there are two fuses and there are relays in the blower motor resistor assembly ! One fuse is located in the under hood fuse / relay box marked RR HVAC Fuse #21 30A Rear Heater, Rear Blower Relays. The other is located in the left Instrument panel fuse block marked IGN 3 10 amp. Fuse # 2. The Blower Motor Resistor Assembly - Auxiliary is In the right rear side panel above the wheel well ! The Fuse Block -Left I/P is On the lower left side of the I/P.Fuse Block - Underhood At the left side of the engine compartment near the battery .
0helpful
1answer

02 Escalade will not start

It will most likely be a poor earth issue, make sure the earth lead between the battery and the body is good and clean and check the one between the body and motor.
Poor earth connections cause excessive current draw and will blow fuses.
0helpful
1answer

My brother just replaced the starter in my 2000 escalade and now it won't start...I seem to remember there was some kind of kill switch or button to push after the alternator was replaced... where is...

There is no "KILL" switch. something isnt hooked up correctly. or a relay is bad/ fuse? I hope the starter wasnt replaced for no reason? Be sure IGN A fuse is good,(under hood fuse box) CRANK fuse, (in dash fuse panel), STARTER RELAY (in under hood fuse box) , battery good? connections tight? shifter in PARK?
0helpful
1answer

Heater has stopped working

(1) possible blown fuse.
Note that fuses blow for a reason - seek out the reason, or it will blow its new fuse too.

The main fuse block is located inside the left side of the engine compartment near the battery. There is also an interior fuse panel located just above the left side kick panel.

Interior Fuse Panel
The interior fuses simply unplug from the fuse panel. Use the fuse puller tool provided with your car to remove fuses from the panel. The tool is located on the back of the interior fuse panel cover.


(2) possible blower motor dead. See maintenance manual excerpt below.

(3) possible blower motor relay faulty. Location of Blower relay:
Under hood, drivers side, front engine area,rear of headlight housing; relay mounted on drivers side of radiator shroud.


1990-92 Mazda 626 and MX-6
See Figure below

archaeology_8.jpg
  1. Disconnect the negative battery cable.
  2. Remove the glove box and the underdash cover.
  3. Detach the electrical connectors from the blower unit.
  4. Remove the blower unit-to-fire wall attaching bolts and remove the blower unit assembly.
  5. Remove the blower motor fan-to-motor fastener.
  6. Remove the blower motor-to-unit attaching bolts, then remove the motor.
  7. Installation is the reverse of the removal procedure.
3helpful
2answers

AC stop blowing 2004 Cadillac Deville, is there a relay or fuse to check before I have to look at the blower

Check the current with a test light at the blower motor.
If it is not getting current, then the fuse or relay is bad.
Check fuses first, as this is the cheapest fix.

2helpful
3answers

My cadillac escalade esv 2003 ran out of gas when I put gas back in It now it won't start or even turnover

my cadillac escalade esv 2003 ran out of gas when I put gas back in It now it won't start or even turnover
1helpful
1answer

Heater AC Problem 99 Escalade

On the passengers side under the dash you will find the blower motor.You might have to remove a panel.By the blower motor there is a blower motor resistor module that gets hot and will melt the connector to the blower motor.Check this area out and if it is melted you need to replace the resistor and the connector.You should be able to get one from the dealership.Hope this helps.Good luck.
2helpful
2answers

04 escalade does nothing when i plug scanner on. its like no power thruogh the wires to the actual plug

Check your fuses...the fuse for the OBII is probaly blowed...Or see if the scanner works in another car, to make sure the internal battery on the scanner is good..
0helpful
1answer

Air and heat not blowing air through vents

Either Your fan switch is burned out or you blower motor is no good, your blower motor is on the passenger side under the dash. Before you replace any parts you need to check your fuses and relays under your hood and in the car. Usually if your fan switch goes bad you will still get some air blowing thru the vents, so my guess would be blower motor, If its not a blown fuse or relay.
Not finding what you are looking for?

166 views

Ask a Question

Usually answered in minutes!

Top Cadillac Experts

ZJ Limited
ZJ Limited

Level 3 Expert

17989 Answers

Thomas Perkins
Thomas Perkins

Level 3 Expert

15088 Answers

Sean Wright
Sean Wright

Level 3 Expert

2045 Answers

Are you a Cadillac Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...