  • Anonymous Oct 07, 2008

    I have an 04 MC SS and i turned on the heat one day and it never turned off even with the key out. I have to unpplug the blower motor fuse in order to turn it off.

  • 04chevymc Oct 07, 2008

    I have the same problem with my 04MC SS. I turned heat on one day and it stayed on with the key out! I have to unplug the blower motor fuse in order to get it out.

  • ryry1988 Dec 06, 2008

    i took my head off the car and i heater was working fine when we got it all back togeather the hearter blower now isnt working.. why would this be..

  • Rustic_Rides Jan 14, 2009

    I have a 1994 S-10 Blazer that has had blower motor isues. TO say the least.
    I have replaced with new or good working used Blower new , Switch NEW X3 , Resistor New, Relay New X2, What else could couse it to act weird??? some times it stays on some times it won't work, It has ben on high working fine for the last 4+ weeks till last night it stayed on and killed the battery. it is now -4 out side & I need to get it figured out. Please HELP

  • Anonymous Jan 22, 2009

    my 2005 silverado heater fan will not run sometime whatever the settings.

    other times the fan will not shut off evan with the key off,and the settings off.The drain kills the battery.the problems are not always present and are very frusterating.

  • Anonymous Feb 05, 2009

    A friend of mine has a 2004 Impala that cant get his blower to turn off, when the keys are out of the ignition. The radio will stay on as well.

    I suspect an issue with 1 or more relays, but dont know for sure. Wish someone had a solution for this. I need a schematic to locate all the relays.

  • Jeremy Elenbaas
    Jeremy Elenbaas May 11, 2010

    What year is the car?

×

3 Answers

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

    Vice President:

    An expert whose answer got voted for 100 times.

  • Master
  • 421 Answers

Your blower motor resistor is shorted and needs to be replaced it is located on the blower box and has 5 or 6 wires going to it there should be two small 7 mm bolts holding it down, you can pull the blower motor relay to shut it off for now untill you get a replacment resistor good luck and please rate -jeff

Posted on Sep 05, 2008

  • Lakewaydrive Dec 04, 2010

    Sometimes it is NOT the resistor that causes this malfunction. Someone needs to post what happens if it is NOT the resitor... then where do you go?

  • Jason Blundo Nov 02, 2012

    I'm on my second resistor. Replaced the motor. Worked fine for a week. Pulled into work today and sure enough motor went full blast and now it's stuck on.

×

  • Level 1:

    An expert who has achieved level 1.

  • Contributor
  • 1 Answer

I had just replace Power Module by the Dearler garage I don't know how do you call it and I'd paied a lot $525 for my vw. Touareg 2004 v6 3.2L .You can see what is it look like. It's working fine but I don't know for how long.blower motor runs all the - f9097819-69e3-44bd-80a2-c6b396808f7b.jpg 974116c2-4db1-4f9a-8176-767b427159fd.jpg

Posted on Sep 12, 2014

  • Level 1:

    An expert who has achieved level 1.

  • Contributor
  • 1 Answer

Heater fan runs all the time with key out 04 impala

Posted on Mar 20, 2009

2 Suggested Answers

wracefans24
  • 1985 Answers

SOURCE: blower motor runs even when vehicle is turned off

you need to check the blower motor resistor.

Posted on Jan 21, 2010

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

2 Answers

A.c. cooling fan runs constantly on high even with ignition off and key out


A/C - Heater blower motor ! What make , model and year vehicle ? Manual or automatic climate control ? Could be a bad blower motor control module , a high blow relay contacts stuck closed .

Mar 28, 2017 | Cars & Trucks

1 Answer

My blower motor quit working changed blower and now it runs all the time even with key off worked fine before blower went out the fuse had also blown what could cause it to run all the time now


Most would say it is the Blower Motor Resistor or a relay..And possibly the dash heater control knob..However it is running all the time even with key off..This means it is getting power all the time from somewhere..It sounds as if wiring is crossed..Did you have to change wiring plug in connectors..?..

Feb 19, 2015 | 2004 Chevrolet Monte Carlo

1 Answer

I cant turn the heater off, it runs all the time


Sounds like the blower motor control module has gone bad. You can find the module under the passenger side of the dash next the blower motor. Power is supplied to the module all the time. If the module fails it can turn on the blower regardless of the key position.

Jan 15, 2013 | 1995 Buick LeSabre

1 Answer

Blower motor runs all time


Either the blower motor relay is stuck closed and running all the time.Relay should be under the hood. Look in the owners manual for the location. Also does it shut off with key or continue to run, Most likely a stuck blower motor relay.

Jun 14, 2012 | 2005 Buick LeSabre

1 Answer

Blower does not run all the time


The blower motor is located under the hood on the passenger side. With the key in the run position and the blower motor switch set on high tap the blower motor with the plastic end of a screwdriver. If it starts to work replace it. If it doesn't start to work check to make sure it has power and a good ground.

Check this link for more help.

Blower motor does not work

Nov 17, 2010 | 1998 Buick LeSabre

1 Answer

Vent fan running all the time even with key out of switch


You have a bad blower motor relay, when the relay goes bad. It can freeze in the on position keeping the contact closed to run your blower motor. Inspect the blower motor relay and wire harness for any short due to burnt wire, this is a common issue with that year of Silverado's
Thank you for using fixya and good luck.

Jun 01, 2010 | 2002 Chevrolet Silverado 1500

1 Answer

Heater airconditioner blower motor runs all the time without ignition switch in run position . runs without the key in the switch. the only way to turn it off is to remove the fuse that powers the blower...


If you haven't fixed this yet, your Blower motor resister module is bad. It is located to the left of the blower motor and mounted in the A/C air box. Just pull the right kick panel down and you will see it.

May 12, 2010 | 1995 Oldsmobile Aurora

2 Answers

HEATER BLOWER MOTOR NOT COMING ON THE BLOWER MOTOR IS GETTING POWER TO THE CENTER BROWN WIRE BUT IT ALSO HAS A BLACK WIRE THE SAME GAUGE AS THE BROWN CENTER WIRE AND A SMALL GAUGE BLACK WIRE ON THE OTHER...


at blower motor connection, disconnect wires and run a 12v line to the positive side of motor and ground the other side if need be. if motor runs then you have a fuse or a wire problem. if it does not run. then blower motor is bad.

Feb 27, 2010 | 2004 Pontiac Bonneville

2 Answers

Blower motor continues to run when vehicle is off


Your problem is the Relay which is encased inside the Heater/AC Resistor Module. This is a very common problem with GMC and Chevy Trucks. The Relay's return spring fails and the relay is held closed by gravity. The only fix is to replace the Resistor Module. I have a 2004 Silverado and have replaced the Module 3 times and the Blower Motor twice. The Orange wire feeding the Module is always Hot (12V) and feeds the Relay Contact for Highest Blower Speed. Hence the Blower runs all the time even with the Key off and removed.

Oct 02, 2009 | 2003 GMC Envoy Xl

2 Answers

Blower motor stays on high, even with key out


the blower motor speed control module is defective, replace it.

Dec 24, 2008 | 2002 Chevrolet Silverado

Not finding what you are looking for?
2004 Chevrolet Monte Carlo Logo

1,381 people viewed this question

Ask a Question

Usually answered in minutes!

Top Chevrolet Experts

yadayada
yadayada

Level 3 Expert

70387 Answers

Colin Stickland
Colin Stickland

Level 3 Expert

22041 Answers

Jeff Turcotte
Jeff Turcotte

Level 3 Expert

6879 Answers

Are you a Chevrolet Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...