-   i'm having a problem when i turn off the car the heater module stays on.please help -   Guest
Feb 04, 2009
-   1995 aurora fan blower will not shut off w key out-   Guest
Dec 23, 2008
-   My '98 Intrigue's low speed heater fan gave up a year ago :( Oh well.
Two day's ago the blower continued to run even with the keys out of the ignition!! Drained my battery :( I pulled the fuse & charged the battery. The engine now starts fine and after reinstalling the fuse the fan ran on its 2 high speeds. Then only on one High speed, then not at all. :) :) The fuse is fine. I disassembled the switch. It appears to function. However, there is power to the switch even with the fuse pulled!! But no fan. I heard no abnormal fan noises i.e. squeeks, squeles, hums or buzzes etc. -   seerofnoj
Dec 20, 2008
-   I have the same problem , i was told that i would need to replace the ignition modulator ,cost about 216.00 bucks more then the beast is worth.
I have not replaced it yet ,also thinking about bypassing this problem with
a manual switch under the dash.
would appreciate input
thks Bob-   Guest
Dec 18, 2008
-   I also have problem with the fan turning on in my 1997 Oldsmobile Regency. I have heat but the fan only works once in a while. Do I need to replace the blower motor or is it something else.
-   stewartfn197
I would start at the fuse. Does the blower motor turn off when the fuse is pulled? A relay is usually used in this circuit and can sometimes "stick" allowing the blower motor to receive constant power. A quick check to see if it is a wiring problem, switch or the relay its self would be to find the blower fan relay and see if there is another one of the value you can swap with it. If the problem goes away, chances are it is the relay but I always like to take a volt/ amp reading to double check my work.
Dan
Is the dipstick on the 5.3 motor
in 1999 Z-71 supposed to read
1/2 way in the operating zone when...
(More)
Is the dipstick on the 5.3 motor
in 1999 Z-71 supposed to read
1/2 way in the operating zone when full 6 qts??
I have a 1995 Legacy LS 4 cyl 4 speed automatic, 201k. I had the transmission fluid and filter...
(More)
I have a 1995 Legacy LS 4 cyl 4 speed automatic, 201k. I had the transmission fluid and filter changed on Thursday, 12/18/09. It was over full at the time I changed it. Got it back and it ran well for a day. Since Friday, it has on occasion lurched and shuddered trying to get into gear (out of first and/or second). I don't know what it means or what is causing this. Any help is appreciated.
headlights keeps burning out after i replace them with new bulbs. the problem is not with just one...
(More)
headlights keeps burning out after i replace them with new bulbs. the problem is not with just one headlight it is with both. no fuses have been blown
1990 olds 98 blower motor stays on key off pulled ac system fuse still on disconnected blower relay still on .disconnect blower resistor module goes off. another web site says replace blower resistor module. twenty bucks plus tax at auto zone. am going to give it a try.blower resistor left top firewall behind dust shield under blower relay.